our product
SINGLE COMPONENT POLYURETHANE INJECTION GROUTING SYSTEM
DESCRIPTION
Perma Inject Hydrogel is a polyurethane injection grouting system. It is a single component product. This product reacts with water to form tough flexible polyurethane foam or an elastomeric gel depending upon the amount of water used in the reaction. This product can be injected into the concrete of RCC structures using a pump where resin is one componenet and the other component is water. Perma inject hydrogel is used in areas of heavy leackages, expansion joint filling cavity filling, in structural concrete and for creating screens.
ACTION
When injected in the concrete Perma Inject Hydrogel reacts with water or moisture to form semi rigid foam or a flexible gel depending upon the quality of water used. It also fills up all capillaries and honeycombs in the concrete to discourage accumulation of water in these pockets at a later stage. Perma Inject Hydrogel is more suited for heavy engineering applications.
ADVANTAGES
Perma Inject Hydrogel seals leakages in all difficult situations such as basements, tunnels and heavily leaking massive structures.
Perma Inject Hydrogel is free from solvents and fillers. It is resistant to hydrolysis and is suitable for use in potable water tanks.
Perma Inject Hydrogel stops the leakage then and there only instantly after injection, there is no waiting period for curing time etc.
DIRECTIONS FOR USE
Clean the surface to be waterproofed and remove the plaster or lose concrete in the area. Assess the leaky area and decide the injection nozzle pattern. The leakage could be either from a horizontal or from vertical crack. Drill holes on either side of the crack at an inclination of 45° inclined towards the centre of the crack at an interval of 8 inch centre to centre. Always start from the lowest point and progress upwards. In the drilled holes fix the packers effectively. In weak concrete the drilled holes becomes larger than desired, in such cases the packer may not fit tightly to a leak-proof fit. If this happens grout the surroundings of the packers with a stiff consistency paste of Perma Plug.
COMPOSITION
Perma Inject Hydrogel consists of a MDI based solvent free, isocyanate component and will only react when it comes in contact with water to produce foam or gel depending on the proportion of water used.
Polymer: water, 1:1 to 1 :5 produces impregnable elastomeric foam
Polymer: Water 1: 9 to 1 :15 produces a highly resilient elastomeric gel.
APPLICATION
SPECIFICATION
Specific Gravity | : | 1.10. to 1.12 |
Viscocity | : | 600 to 800 mPa.s |
Flash Point | : | > 150°C . |
REACTION TIME
RATIO Hydrogel : Water | CREAM Seconds | GEL Seconds | END PRODUCT |
1: 1 | 20-30 | 50-60 | Foam |
1:4 | 60-80 | 110-130 | Strong Gel |
1:5 | 80-100 | 120-140 | Strong Gel |
1:10 | 3-4 min | 6-8 min | Gel |
1:12 | 4-6 min | 14-16 min | Gel |
1:15 | 14-16 min | 35-40 min | Soft Gel |
HEALTH AND SAFETY
The workers should use mask and hand gloves to avoid direct breathing of the toxic vapors and to avoid direct contact with the skin. Ventilate the working area adequately maintain over all hygienic conditions. Clean the tools and the pumps immediately after use.
PACKING
Perma inject Hydrogel is available in packing of 25 Kg and 5 Kg tins.
SHELF LIFE AND STORAGE
Perma inject Hydrogel has a shelf life of 9 months from date of manufacture. These products are both temperature and moisture sensitive. Hence it is of utmosrt importance that these products are stores in DRY CONDITIONS BETWEEN TEMPERATURES 10 to 30 degree.
DISCLAIMER
PERMA warrants that all products are free from any defects of manufacture and comply with the specifications given in their respective technical data sheet. No warranty can be given as to the results of use because conditions of use, such as site conditions, surface preparations, workmanship, weather, structural issues and other factors are beyond the control of PERMA. Purchaser agrees to seek the advice of qualified professionals to carry out tests & take trials to determine the suitability of products for their intended purpose prior to full scale usage of PERMA products and assumes all risks.
The company does not assume any liability for unsatisfactory results, arising from the use of our products. Purchaser’s sole liability is limited to replacement of product or refund of the purchase price paid if any product proven defective. No other warranties, express or implied, shall apply including any warranty of merchantability or fitness for a particular purpose.
PERMA shall not be liable for any consequential damages arising from the use of our products for unsatisfactory results.
The information supplied in this datasheet is based on our experience through extensive research and is given in good faith in order to help prospective users. We reserve the right to update the information provided in our technical data sheet at any time without prior notice within the scope of technical progress or new developments.